Classical IIR Filters, Continuous Time
The Analog Filter Design block designs and applies continuous-time IIR filters with standard band configurations.

All of the analog filter designs let you specify a filter order. The other available parameters depend on the filter type and band configuration, as shown below, where
0 = cutoff frequency,
1 = lower cutoff frequency,
2 = upper cutoff frequency, Rp = passband ripple in decibels, and Rs = stopband ripple in decibels.
Configuration
|
Butterworth
|
Chebyshev I
|
Chebyshev II
|
Elliptic
|
Lowpass
|
0
|
0, Rp
|
0, Rs
|
0, Rp, Rs
|
Highpass
|
0
|
0, Rp
|
0, Rs
|
0, Rp, Rs
|
Bandpass
|
1, 2
|
1, 2, Rp
|
1, 2, Rs
|
1, 2, Rp, Rs
|
Bandstop
|
1, 2
|
1, 2, Rp
|
1, 2, Rs
|
1, 2, Rp, Rs
|
For all of the analog filter designs, frequency parameters are in units of radians per second.
The block uses a state-space filter representation, and applies the filter using the State-Space block in the Simulink Continuous library. All of the design methods use Signal Processing Toolbox functions to design the filter:
For more information on the filter design algorithms, see the Signal Processing Toolbox User's Guide.
[ Previous | Help Desk | Next ]