DSP Blockset
  Go to block:
    Search    Help Desk 

Classical IIR Filters, Continuous Time

The Analog Filter Design block designs and applies continuous-time IIR filters with standard band configurations.

All of the analog filter designs let you specify a filter order. The other available parameters depend on the filter type and band configuration, as shown below, where 0 = cutoff frequency, 1 = lower cutoff frequency, 2 = upper cutoff frequency, Rp = passband ripple in decibels, and Rs = stopband ripple in decibels.

Configuration
Butterworth
Chebyshev I
Chebyshev II
Elliptic
Lowpass
0
0, Rp
0, Rs
0, Rp, Rs
Highpass
0
0, Rp
0, Rs
0, Rp, Rs
Bandpass
1, 2
1, 2, Rp
1, 2, Rs
1, 2, Rp, Rs
Bandstop
1, 2
1, 2, Rp
1, 2, Rs
1, 2, Rp, Rs

For all of the analog filter designs, frequency parameters are in units of radians per second.

The block uses a state-space filter representation, and applies the filter using the State-Space block in the Simulink Continuous library. All of the design methods use Signal Processing Toolbox functions to design the filter:

For more information on the filter design algorithms, see the Signal Processing Toolbox User's Guide.



[ Previous | Help Desk | Next ]